NDT Reports for Castings: What a Report Must State to Be Worth Anything

NDT technician reviewing a radiograph of a casting on a light box in a foundry darkroom

Got an NDT report that says “passed”? That is a verdict, not a result. Send it over and we will tell you what is missing — method, standard, acceptance level, coverage, operator certification — before your customer’s auditor asks the same question.

Request an NDT report review →

An NDT report is the document that tells you whether a casting is sound inside. It is also, in a large share of shipments from new suppliers, a single page that says “NDT: OK” and is signed by nobody in particular.

The gap between those two things is not a technicality. It is the difference between having inspected a casting and having asserted that it is fine.

Four methods, four different questions

MethodFindsTypical use on castings
Radiography (RT)Internal volumetric defects: shrinkage, gas porosity, inclusionsPressure-tight, safety-critical, wall sections up to ~50 mm
Ultrasonic (UT)Internal defects, particularly in thick sections and near surfacesHeavy castings, thick walls, areas RT cannot reach
Magnetic particle (MT)Surface and near-surface indications in ferromagnetic alloysIron and steel castings, weld repair areas
Penetrant (PT)Surface-breaking indications, any materialAluminium, austenitic stainless, machined surfaces

The methods are not interchangeable and they do not overlap much. Radiography will not tell you about a surface crack that penetrant finds instantly, and penetrant will tell you nothing about a shrinkage cavity 8 mm below the skin. If your specification says “NDT” without naming a method, you have specified nothing, and the cheapest available method will be applied.

The eight fields every report needs

  1. Method and standard — for example “RT per ASTM E94” or “PT per ASTM E165”. The standard defines the technique; without it the result is not reproducible.
  2. Acceptance level — the severity threshold, ideally by reference to a standard’s reference images or categories, and ideally quoted from your drawing or purchase order.
  3. Coverage — percentage of the defined area examined, or a named sampling plan with locations.
  4. Technique parameters — for radiography: voltage, film class or detector, source-to-object distance, image quality indicator value. For penetrant: penetrant type, dwell time, developer. These are what make a result repeatable.
  5. Part identification — part number, drawing revision, heat number, quantity examined, and the specific pieces if the inspection was not 100 percent.
  6. Results by area — indication type, size, location and disposition for each finding, not just a global verdict.
  7. Operator and certification — name, level, certification scheme, certificate number.
  8. The original images — films, or digital files, retained and retrievable.

A report missing fields 1, 2 or 3 cannot be evaluated at all. A report missing field 6 tells you the outcome without telling you what was found, which means you cannot judge whether the acceptance level was applied correctly.

“Passed” is not a result

The single most common defect in NDT documentation from new suppliers is a report that records a verdict instead of findings. It happens for an understandable reason: a verdict is what the customer asked for, and writing findings invites argument.

But a verdict without an acceptance criterion is unfalsifiable. “Passed” against what level, in which areas, at what coverage, judged by whom? If the answer to any of those is not in the document, the document is a claim.

Ask for the finding list even when the result is a pass. A report that says “three indications of shrinkage, largest 2 mm, all below Level 2 acceptance, locations marked on the attached sketch” is worth ten pages of ticks. It also tells you where the process is marginal, which is exactly where you want to look first when a problem appears six months later.

Radiograph of a casting on a light box showing an internal indication
An original radiograph shows where the indication sits. A summary line does not.

Coverage: the quiet loophole

A report can be fully compliant and still have examined almost nothing. Castings are large; the areas where shrinkage and gas defects concentrate are specific — thermal hot spots, heavy-to-thin transitions, gates and risers, core-bearing surfaces. If the inspection covered a convenient flat area and missed the hot spot, the pass is meaningless.

Specify coverage as one of:

For a first article or a new tool, 100 percent of the critical regions is the right answer regardless of what production will use. The point of the first article is to find out where the process is weak; sampling is for parts whose process you already understand.

Certification: check the scope, not just the level

ISO 9712 Level 2 is the normal requirement for the operator who performs and interprets the test. Two things to check beyond the number:

You do not need to verify the certificate with the issuing body. You need the certificate number on the report, and you need it to match the method. That alone eliminates most of the reports that were assembled by somebody copying a template.

Repair and re-inspection: the part nobody documents

NDT finds something on most first articles. What happens next is a separate documentation question, and it is the one that most often goes unrecorded.

Weld repair of castings is normal and legitimate — ASTM A488 exists precisely to govern it — but it is only acceptable if three things are true:

Ask for the repair rate as a number on the first article. A foundry that reports 2 percent repairs is monitoring something; a foundry that reports zero is either very good or not recording. Then ask to see a repair record for a recent part. The answer is more informative than any certificate.

There is a second, quieter version of this problem: re-inspection that happens in order to obtain a pass rather than to establish a result. If a report shows an area inspected three times and passed on the third attempt, that is not a pass — it is a marginal process and a documentation trail that should tell you so.

Write the requirement before the order

The reason NDT documentation disappoints is almost always that the requirement was expressed as a word rather than a specification. Four lines in a purchase order fix it:

That is a paragraph of text. It is also the difference between a document that protects you and one that merely postpones the conversation.

Related verification pages

Specify the NDT before you order

Tell us the part, the service condition and what your customer requires. We specify the method, the standard, the acceptance level and the coverage in writing, so the report you receive can be checked against a requirement rather than judged on trust.

Prefer email? cfwc@163.com · WhatsApp +86 159 4126 7000